FX3U 24MT6AD2DA 14 input 10 transistor output 6 analog input 2 analog output plc controller
FX3U 24MT6AD2DA PLC programmable logic controller
FX3U 24MT——14 point input 10 transistor outputs, 3 channcel o-v10,3 channel 0-20mA), 2 analog outputs(0-10V)
1. 3 channel AB input,
2. Support 1N, 2N, 3U instruction
3. Program 8,000 steps,
4. The download speed 38400
5. Support Mitsubishi GX-Develoer, GX-WORK2
6. Support HMI connection, the application is completely identical to the Mitsubishi FX3U.
7. The PLC with industrial-grade 32-bit MCU, and run much faster than Mitsubishi FX3U.
Input Power |
DC24 |
Number of steps |
8000 steps; 2 communication ports: 1 RS232 (DB9 serial port is communication port for the FX3u protocol 38400,7,E,1; 1 RS485 (485 selection) communication protocol can be set D8120). |
X input element |
DC24, X0-X27 input,Low level X0-5 is a high-speed count input port (Default is 12K, 100KHZ optional) |
Y output element |
Y0-Y3 transistor output,transistor output Current 500mA, plus the diode can achieve 4A. 100K 4 Channel Pulse output Y4-Y11 Transistor common output, can be directly driven 3A 24V load |
Analog input |
6 analog input, 12 bit precision, A0-AD2: 0-10V, A3-AD5 :0-20MA; read analog RD3A instruction。 |
Analog output |
2 analog output, 12 bit precision, output voltage: 0-10V. output analog voltage with WR3A instruction |
Intermediate relay M |
M0-M3071, the scope of power loss saving can be set up.Rang M0-M1023 |
Stepper Point S |
S0-1023, power down save range can be set up S0-S1023,Default is S500-S999 |
100Ms Timer |
T0-T199, cumulative power down save T184-T199 |
10Ms Timer |
T200-T249, cumulative power down save T246-T249 |
1Ms Timer |
T250-T383,T250-255 is the cumulative type |
16-bit counter |
C0-C199, power down save C100-199 |
32-bit counter |
C200-C219, power down save C220-C234 |
32-bit high-speed counter |
C235-255;C235-240 for the single-phase counter, Non harmonic; |
Register D |
D0-D7999, power-down save range can be set D0-7999 |
Indirect addressing pointer V, Z |
V0-7,Z0-7 |
P subroutine jump number |
P0-63 |
I interrupt |
X0-5 external interrupt. Timer interrupt (1MS units). Timer interrupt. |
Special element M |
M8000 running normally closed,M8002 power pulse,M8011 is 10Ms pulse,M8012 is 100Ms pulse,M8013 is 1s pulse,M8014 minutes pulse. |
-
HMI WECON (26/10)
-
V-BOX LÀ GÌ (11/09)
-
Biến tần cho động cơ 1 pha (06/07)
-
Hướng dẫn sử dụng nhanh phần mềm lập trình HMI Delta DOPSoft (11/07)
-
Hướng dẫn cài đặt phần mềm lập trình PLC Delta DVP (02/03)
-
Động cơ servo- Part 3- Servo là gì? (29/06)
-
Động cơ servo- Part 2- Các khái niệm cơ bản về động cơ servo (29/06)
-
Động cơ servo- Part 1- Lựa chọn động cơ servo (29/06)
-
Giám sát điều khiển qua internet và mobile app: HMI, Biến tần, Sensor, PLC (18/05)
-
PLC Wifi - PLC GPRS -Giải pháp giám sát, điều khiển PLC qua internet (modbile app, PC, Web) (24/04)